1. On main ‘HEC-RAS’ window click on Edit -->Steady Flow Data
2. On ‘Steady Flow Data’ window, enter the flow value, which is 13 m3/s.
3. On ‘Steady Flow Data’ window, click on ‘Reach Boundary Conditions’
4. On ‘Steady Flow Boundary Conditions’ window, first Click on blank cell below Downstream column and then click on ‘Normal Depth.
5. On new Window enter the value of slope given in Exercise statement. The value of slope is 0.005. and Press ‘OK’.
6. On ‘Steady Flow Boundary Conditions’ window, Press ‘OK’
7. On ‘Steady Flow Data’ window click on File-->Save Flow Data
a. Give and appropriate title and Press OK.
8. Close ‘Steady Flow Data’ Window